GENERAL NOTES:- THIS DOCUMENT IS IN ACCORDANCE WITH ASME Y14.5M 2009.- ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE SPECIFIED.- THIS DRAWING IS A LIMITED DIMENSION PRINT CREATED FROM A 3D SOLID MODEL. FORADDITIONAL DIMENSIONAL INFORMATION REFER TO THE CAD MODEL;- ANY CHANGES MADE TO THE DRAWING, MUST ALSO BE MADE TO THE CAD MODEL;- PARTS MUST BE FREE OF ALL BURRS, SHARP EDGES AND FOREIGN MATERIAL THAT MAYAFFECT FIT AND FUNCTION, OR SAFE HANDLING AS DETERMINED BY STACKPOLE INT.- ALL PARTS MUST BE PROTECTED AGAINST OXIDATION FOR A 6 WEEK SHELF LIFEFROM ARRIVAL AT STACKPOLE PLANT UNLESS OTHERWISE SPECIFIED BYSTACKPOLE INTERNATIONAL.- FOR FERROUS MATERIALS MAXIMUM MAGNETIC FIELD ALLOWABLE 5 GAUSS.- CENTRELESS GROUND DIAMETERS MUST BE MEASURED USING A 3 POINT MEASURINGTECHNIQUE