This machine data defines which stop conditions are to be ignored at an ASUBstart. The ASUB is started, or the following stop conditions are ignored:Bit 0 :STOP reason: STOP key , M0 or M01An ASUB is started immediately if NCK is in RESET state (or JOG mode) (no ASUB can be started in RESET/JOG without this bit) .NOTICE:- This bit is set implicitly if $MC_PROG_EVENT_MASK deviates from zero in a channel!- This bit is set implicitly if BIT 1 is set in $MN_SEARCH_RUN_MODE!Bit 1 :Start allowed even if not all axes have yet been referenced.Bit 2:Start allowed even if a read-in disable is active, that is the blocks of the ASUB program are loaded and executed immediately. This disables machine data IGNORE_INHIBIT_ASUP. The NCK behavior corresponds to the machine data contents of IGNORE_INHIBIT_ASUP== FFFFFFFF.If the bit is not set:then the ASUB is internally selected, but not processed until the read-in disable is canceled.