At the same density, the permeability of low density cement slurry system and conventional cement slurry system decreases with the increase of temperature. At the same time, with the increase of hardening temperature of cement paste, the hydration rate of cement slurry is accelerated, and the formation rate of hydrated calcium silicate and other substances is accelerated, resulting in the decrease of cement permeability.